Fluoroscopy is a type of medical imaging that shows a continuous X-ray image on a screen, it is used in a wide range of examination and procedures for diagnosis such as in cardiac catheterization. Fluoroscopy can result in relatively high radiation doses, especially for complex interventional procedures that it needed to monitor radiation to reduce exposure. The purpose of this study is to determine the radiation doses for patients during cardiac catheterization exam and compare it with the permissible dose limits. The main parameters which are studied in this work are the time of exposure dose rate, x-ray techniques (milliamper. second), tube voltage (kilovolt) and Dose Area Product (DAP). Twenty-seven patients were included and absorbed doses were measured and distributed according to Fluoroscopy (Fluo) time, mAs and Dose Area Product (DPA). It was found that the absorbed dose received by the patients has a linear relationship with the Fluoroscopy time, mAs and DAP. Exposure dose rates were measured and compared with the maximum permissible dose (100 mGy/min), the estimated patient dose rate varied from (12-81.6) mGy/min) for 24 patients as a permissible dose in the safe side, and 3 patients exposed to higher values of the exposure dose rates ) over permissible dose) range (107.4-108) mGy/min
Downloads
References
Vano, Eliseo, et al. "Conversion factors to estimate effective doses from kerma area product in interventional cardiology. Impact of added filtration." Physica Medica 68 (2019): 104-111.
Bushong, Stewart C. Radiologic science for technologists-E-book: physics, biology, and protection. Elsevier Health Sciences, 2013.
Miller DL1, Balter S, Cole PE “ Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose 2003 Jun;14(6):711-27. .
Al-Qurayshi. M.R.,Al-Mosawi.H.Q."Radiation physics and its applications in diagnostic radiological techniques."(2015).
Davis, Cheri, et al. "Vascular complications of coronary interventions." Heart & Lung: The Journal of Acute and Critical Care 26.2 (1997): 118-127.
Chong, N. S., et al. "Evaluation of absorbed radiation dose to working staff during cardiac catheterization procedures." Zhonghua yi xue za zhi= Chinese medical journal; Free China ed 63.11 (2000): 816-821.
Goni, H., et al. "Investigation of occupational radiation exposure during interventional cardiac catheterisations performed via radial artery." Radiation protection dosimetry117.1-3 (2005): 107-110.
Alkhawad, Safaa Ibrahim Awad Elkarim. "Dose-area product measurement for patients in diagnostic radiography." (2001).
Recommendations of the International Commission on Radiological Protection. Publication 60 (Pergamon Press), International Commission on Radiation Protection. ICRP (1990).
International Basic Safety Standards (BSS) for protection against ionizing radiation and for the safety of radiation sources, IAEA (1996).No 115, Vienna.
Wagner LK, Archer BR. "Minimizing risks from fluoroscopic x-rays 2nd ed". Houston, TX: Partners in Radiation Management, 1998.